I am currently handling Max10M16DAF256 and i also have trouble with the new ADC. When using .sof file it truly does work okay. While using .pof document the new ADC can not work any further, i.e ADC data is constantly zero, since the anyone else portion work precisely.

Therefore for some reason the ADC state describes the power have sequence while the ramp time of stamina supplies, but a definite explanation for it situation might have been maybe not found yet

mail order bride virgin

You will find together with viewed whenever programming having .pof document nevertheless let the suppy current toward, the brand new ADC performs. But once reset the supply current (switch off as well as on once again), it will not functions any more.

If the latter then you need to verify check the method that you launch the ADC Internet protocol address from reset. Hold on a minute during the reset ‘a little longer’ pursuing the power up. Disappointed this may sound a small obscure. That it is apparently a frequent matter toward message board you to definitely will not appear to have received an obvious, reliable services.

Should this be their board you will need to check on these and ensure the fresh rail go up monotonically. There are not any sequencing conditions but if the dont go up rightly – maybe not appointment the fresh new Tramp big date – the system will misbehave. Refer to ‘Figure step three. Tracked Strength Supplies Ramp Up’ regarding the ‘ energy government representative publication (

I additionally found the same kissbridesdate.com web sites issue with Max10 ADC in another thread, however, like you said there is no service because of it.

The board are our worry about framework board. The issue is that many of our forums will work okay having ” .pof “-file, and some of those have this ADC condition. To the chatrooms which have ADC disease, we investigated from the equipment ones forums but unfortunately i didn’t find any issue into the apparatus. Such as mentioned above, new forums work having ” .sof ” as well as ” .pof “-file if supply current is always to your.

This will make me personally trust far more this dilemma can be fuel associated. I believe you’ve got one (or even more) somewhat slow otherwise less than rated supplies. You’re obviously to the side of whatever the issue is provided you’ve got operating chatrooms.

Can you bring a non working panel, unplug the advantage provides and energy they of bench supplies? My concern is that an under rated rail isn’t really to supplying the inrush required and dips resulting in the POR circuitry a great problem, hence (perhaps) isn’t reported.

You may be correct. Used to do some analysis in the electricity provides for Max10, plus it appears like our analog also provide requires some much time until they reaches full voltage peak (we’re having fun with Max10 dual supply equipment, and this requires a couple electronic supplies and you may 1 analog have).

Like in Max10 Strength management associate guide, it looks like precisely the past battery pack to possess Max10 amount (attached image), so we made an effort to swtich for the analogue also provide basic and you can watch for it to-arrive max height, right after which turn on another several digital provides, and this need just couple hundred s to reach maximum height. This will help the fresh not-working ADC to become working sporatically (not necessarily working).

But when i get a working board (ADC constantly really works) and you may perform the reverse succession (i.age let a couple of digital provides to the very first, then the analog supply), the latest ADC remains performing (i requested which should not work any further).

Following the supply current is reset, the new ADC really does no longer works as rest remains operating correctly

LEAVE A COMMENT

You comment will be published within 24 hours.

ONLINE APPOINTMENT

Book your appointment now and get $5 discount.

MAKE APPOINTMENT
LATEST POSTS
MOST VIEWED
TEXT WIDGET

Here is a text widget settings ipsum lore tora dolor sit amet velum. Maecenas est velum, gravida vehicula dolor

CATEGORIES

پارس یدک طراحی شده توسط پارسا آقایی © Copyright 2016